Productdetails
Basic Features
Method
Sheet thicknesses
- to max. 38 mm separating cut
Base materials
- all electrically conductive metals, also coated
- stainless steel
- Aluminum
- steel
- Non-ferrous metals
Typical applications
- Plant, container, machine, steel construction
- chemical plant
- Repair / Repair
- Industrial plant and pipeline construction
- Construction site and installation
Description
- Suitable for use on generator e.g. in company workshops, harbors, chemical plants, schools, metalworking, on construction sites, ships or for farmers
- For stainless steel, aluminum, steel, non-ferrous metals also with painted surface
- From thin sheets to heavy plates
- Pilot ARC controller: The set welding current is released only after the arc has been ignited
CRAFT-CUT 41 P
- Power Factor Correction PFC enables cable reel operation
CRAFT-CUT 123 CNC
- CNC interface for machine connection
Cutting performance |
---|
Quality cutting steel (ST37) max. | 32 mm |
Separating cut steel (ST37) max. | 38 mm |
Quality cutting stainless steel max. | 32 mm |
Separating cut stainless steel max. | 38 mm |
Quality cutting aluminium max. | 22 mm |
Separating cut aluminium max. | 28 mm |
Device data |
---|
Air consumption | 160 l/min |
Pressure | 5 bar |
Dimensions and weights |
---|
Length approx. | 700 mm |
Width/depth approx. | 240 mm |
Height approx. | 445 mm |
Weight approx. | 28.8 kg |
Duty cycle |
---|
Duty cycle plasma | 60 % |
Current at 100% DC 40°C Plasma | 65 A |
Electrical connections |
---|
Input current | 20 A |
Electrical Data |
---|
Supply voltage | 400 V |
Mains frequency | 50/60 Hz |
Setting range |
---|
Adjusting range plasma approx. | 20 – 80 A |
Standards and certifications |
---|
Standard | IEC 60974-1:2012 |
EMC class | A |
Explanation EMC class | This Class A welding equipment is not intended for use in residential areas where power is supplied by a public low-voltage power supply system. |
Marking | CE |
Unit: pc(s).
Packaging unit: 1
- Plasma torch PLUSCUT 85 6m
- Central adapter Trafimector
- Earth cable 3 m, 12 mm² with earth terminal 300 A
- Filter pressure regulator with plug nipple